top of page

TRANE XR14 3 Ton Heat Pump Condenser

 

Mechanical Specification Options


General
The outdoor condensing units are factory charged with the system charge required for the
outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor
evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high
as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils
that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor
application.
Casing
Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant
powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour
salt spray test .


Refrigerant Controls
Refrigeration system controls include condenser fan, compressor contactor and low and high
pressure switches. A factory supplied, field installed liquid line drier is standard.
Compressor
The compressor features internal over temperature and pressure protection. Other features
include: Centrifugal oil pump and low vibration and noise.


Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected
on all four sides by louvered panels.


Low Ambient Cooling
As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator
defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV
permits low ambient cooling to 30°F.


The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F.


Thermostats—Cooling only and heat/cooling (manual and automatic change over). Sub-base to
match thermostat and locking thermostat cover.

 

Technical Specs
Airflow CFM 3,440
Blower Fan Speeds 1
Charging Specification Subcooling 10 Deg. F
Coil Face Area (Sq-Ft) 19.1
Coil Rows 1
Coil Type Spine Fin
Color Tarpaulin Gray
Compressor Insulation/Sound Blanket No
Compressor LRA 72.2
Compressor Power Rating 208-230V/1Phase/60Hz
Compressor RLA 14.1
Compressor Sump Heater Factory Installed No
Compressor Type Scroll
EER 11.5
EER2 11.7
ElecPhases 1
ElecVolts 208-230V
Energy Star Compliant No
Factory Charged Yes
Fan Drive Direct
Fan Motor FLA 0.64
FAN MOTOR HP 1/5
Fan Type Propeller
FPI 24
Frequency (Hz) 60
Full Octave Sound Power[dB] 84 at 63Hz, 75 at 125Hz, 70 at 250Hz, 72 at 500Hz, 67 at 1000Hz, 62 at 2000Hz, 57 at 4000Hz, 50 at 8000Hz
HSPF 8.2
HSPF2 7.5
Material G90 Galvanized Steel
Max Fuse 30A
Max SEER 15
Max SEER2 14.3
MCA 19
Min Amp Rating 19
Min SEER 14
Min SEER2 14.3
Model-Phase 1
Motor (RPM) 825
Motor HP 1/5
Motor Power Rating 208-230V/1Phase/60Hz
Nominal Capacity BTU Rating 36,000
Number of Compressor 1
Number of Fan Motors 1
Number of Fans 1
Number of Phase 1
Outdoor Coil-Tube Size (In) 3/8
Power Supply 208-230V/1Phase/60Hz
Refrigerant Charge lbs 6 lbs-12 Oz.
Refrigerant Control Expansion Valve
Refrigerant Type R-410A
SEER 14
SEER2 14.3
Shipping Weight 248.0
Sound Level (dB) 75
Sound Rating (dB) 75 dB(A)
Split System Connection Brazed
Stages 1
Standards AHRI, cETL US
Start Kit Model Number (Field-Supplied) No
Tier XR14
Uncrated Dimensions (HxWxD) 29.13 X 37.25 X 34.25 in.
Voltage 208-230V
Description UNIT; 4TWR; 14 SEER; 35,000 BTUH; R-410A SPLIT SYSTEM HEAT PUMP; 200-230/1/60
Long Description SPLIT SYSTEM HEAT PUMP; 200-230/1/60

 

 

TRANE XR14 3 Ton Heat Pump Condenser